Jugo Magnet: The difference between a fluxmeter and a gauss meter

About fluxmeter and gauss meter, a lot of people to these two kinds of magnetic measuring instrument is not quite clear, they are the NdFeB magnet manufacturers commonly used measuring instrument, what is the difference between them?What are the advantages and disadvantages of each?

1,Fluxmeter

The magnetometer is a unit of magnetic material or object's whole performance unit by using the principle of electronic integration.General units: mWb, Wb and other units to represent.

Advantages of fluxmeter: it is an ideal instrument for measuring magnetic field and magnetic flux.The measurement is the overall average value of the magnet, which can reflect the overall performance of the magnet. The value of magnetic flux can be completely compared and transferred. Magnetic flux can reflect the overall performance of the magnet.On the contrary, the performance of magnetic flux must be good (the combination of all magnetic field lines in the body of the magnet).

Disadvantages of fluxmeter: for each type of magnet sample of different specifications, coils of different sizes must be made. Strictly speaking, for very thin samples, the preparation difficulty of detecting coils is also relatively large, which is troublesome and inefficient.

1-1Z4100Z42EI.png

2,Gauss meter

also known as a teslameter, USES holl's principle to measure the magnetic induction intensity of a point and a surface on a magnetic material or object.

Gauss meter advantages: convenient, intuitive, easy to carry.

Gauss meter faults: point test, uncertainty of measuring different people, different manufacturers gauss meter to measure the value of the different, the same gauss meter probe measurement value is different, different test data, there is a lot of divergent, is the cause of gauss meter sensor chip, probe encapsulation thickness, the position of the chip, gaussian value is hard to be the same point test, the test chip size to differ, and uneven table magnets, gauss meter factory standard is calibration in the uniform magnetic field, so the gauss meter measuring the value of it is difficult to unity and alignment.

1-1Z4100Z405C2.jpg

Above is the difference between fluxmeter and gauss meter and the advantages and disadvantages of the introduction, more questions welcome to consult Jugo Magnet